MARS L2 — WET cabinet hardware BOM
WET variant: Industrial PC + Power cabinet with UPS. PLC is line-side;
L2 talks to it over the fieldbus but does not own the PLC cabinet.
Industrial PC cabinet
| Component |
Specification |
Notes |
| IPC |
Monoblock with sensor touchscreen, IP65 |
≥ 8 GB RAM, ≥ 128 GB SSD, 2× Ethernet, 2× USB 3.0, RS-232/485 required (UPS) |
| OS |
RED OS 7/8 or Debian 12 |
|
| Physical controls |
"Сброс аварии" button + status LEDs |
GPIO header or USB-GPIO |
Power cabinet
| Component |
Specification |
Notes |
| UPS |
ОВЕН ИБП120К |
Mandatory for WET. RS-232 / USB-CDC monitored by L2 |
| Modular distribution |
DIN-rail breakers, 24 V rail, SPDs |
Standard MARS profile |
| Reserved Point-I/O area |
~10 DIN slots |
Future expansion |
Protocols in use (WET)
- L2 ↔ UPS: OWEN IBP120K over RS-232 / USB-CDC (fallback: NUT TCP 3493).
- L2 ↔ PLC (line-side): Modbus TCP / OPC UA / EtherNet/IP depending on
the existing line PLC.
- L2 ↔ scanners: TCP / Serial / USB-HID.
- L2 ↔ printers: TCP / USB / Bluetooth (mobile printers).
Supported device matrix (out of the box)
All drivers below ship in the edge-service package and can be activated
from the L2 Settings UI without a firmware rebuild. Wire-format compliance
is asserted by ProposalDriverComplianceTest (16 tests).
Fixed scanners
| Vendor / family |
Transport |
Protocol |
Default port |
| Cognex DataMan 2xx/3xx |
TCP |
DMCC ||>cmd<| |
23 |
| Cognex DataMan (industr.) |
TCP |
DMCC + CONFIG.SET-INDUSTRIAL-PROTOCOL (EtherNet/IP, Profinet, Modbus TCP, SLMP, CC-Link) |
23 |
| Hikrobot ID3000/5000 |
TCP |
MVS-ID ASCII |
2001 |
| Datalogic Matrix 120/210/220 |
TCP |
HOST MODE ASCII |
51236 |
| Keyence SR-X300 / SR-1000 |
TCP split cmd/data |
Keyence ASCII |
9004 / 9005 |
| SICK Lector 6xx / CLV6xx |
TCP |
CoLa A (STX/ETX framing) |
2112 |
| Omron MicroHAWK V320/V330 |
TCP |
ASCII K-commands |
2001 |
| Zebra DS3678 / DS9908 |
TCP |
SSI (length/opcode/chk) |
23 |
| Generic |
TCP / Serial |
line-delimited raw |
any |
Handheld scanners
| Vendor / family |
Transport |
Mode |
| Datalogic Gryphon / QuickScan |
USB |
HID keyboard wedge |
| Honeywell Xenon 1900/1902 |
USB |
HID keyboard wedge |
| Newland HR / NVH series |
USB |
HID keyboard wedge |
Printers
| Vendor / family |
Kind |
Protocol |
Default port |
| Videojet 1000-series |
CIJ |
CLARiTY Text (CR terminator) |
3003 |
| Videojet Wolke 660/670 |
TIJ |
Wolke ASCII |
3003 |
| Domino Ax-Series |
CIJ |
QuickDesign remote ASCII |
9100 |
| Hitachi UX-161 / UX2-361 / KC |
CIJ |
Modbus TCP (code + trigger registers) |
502 |
| Linx 7900 / 8900 |
CIJ |
Linx LX-protocol |
3010 |
| Markem-Imaje SmartDate X-series / 9410 |
TTO |
NGPCL |
4001 |
| Novexx XLP 504 / 514 |
LAS |
EasyPlug |
9100 |
| SATO CL4NX / CL6NX |
Label |
SBPL (STX/ETX) |
9100 |
| Zebra ZT / ZE industrial |
Label |
ZPL |
9100 |
| Godex G-series |
Label |
EZPL |
9100 |
| TSC TTP / MH / MX |
Label |
TSPL / TSPL2 |
9100 |
| Solmark (mobile) |
Thermal |
ZPL |
9100 |
PLCs
| Vendor / family |
Transport |
Protocol |
Notes |
| Any Modbus TCP master |
TCP |
Modbus/TCP FC 03/04/06/16 |
Default |
| Any Modbus RTU master |
RS-485 |
Modbus/RTU (jSerialComm + CRC16) |
WET UPS path |
| Any OPC UA server |
TCP |
OPC UA via Eclipse Milo + subscriptions |
Push updates |
| EtherNet/IP |
TCP |
CIP over EtherNet/IP |
Allen-Bradley |
| Siemens S7-1200 / S7-1500 |
TCP |
Modbus TCP via MB_SERVER FB |
Siemens SIOS 109768624 |
| Profinet (via MOXA MGate 5103) |
TCP |
Modbus TCP ↔ Profinet IO gateway |
Proposal §3.2 |
| Generic TCP socket |
TCP |
line-delimited telemetry |
Fallback |
UPS
| Vendor / family |
Transport |
Protocol |
| ОВЕН ИБП120К |
RS-232 / USB-CDC |
Megatec Q1 (2400 8N1) |
| Any NUT-managed UPS |
TCP |
Network UPS Tools client (3493) |
UPS wiring
- Primary: RS-232 DB9 cable from UPS to IPC's COM1 (
/dev/ttyS0).
- Fallback: USB-CDC (IPC enumerates
/dev/ttyACM0 or /dev/ttyUSB0).
- Relay output of UPS → status LED or optional external buzzer.
- Configure in
edge-service.yaml:
ups:
type: OWEN_IBP120K
transport: RS232
devicePath: /dev/ttyS0
baudRate: 9600
pollIntervalMs: 2000
lowBatteryPercent: 40
criticalBatteryPercent: 20
shutdownRelayGpio: gpiochip0:27
Deployment checklist
- Install RED OS / Debian.
- Install the
.rpm / .deb package.
VARIANT=wet SITE=<LUZ|NOV|MIR|RND> sudo -E bash install.sh.
- Verify
GET /api/v1/ups/status returns connected=true.
- Simulate a mains cut (physically or
POST /api/v1/ups/simulate) and confirm the journal shows
UPS_ON_BATTERY followed by UPS_RESTORED after power returns.
- Run the HIL matrix from
load-test/HIL_BENCH.md
with the UPS row enabled.